Impacto da valvoplastia pulmonar por balão em pacientes portadores de estenose pulmonar valvar em hospital terciário de Salvador – Bahia

dc.contributor.advisorLADEIA, Ana Marice Teixeira
dc.contributor.authorAROUCA, Aline do Aido Varanda
dc.contributor.refereesRITT, Luiz Eduardo Fonteles
dc.contributor.refereesCÂMARA, Edmundo José Nassri
dc.contributor.refereesRONDON, Atila Victal
dc.date.accessioned2025-12-01T12:29:31Z
dc.date.available2025-12-01T12:29:31Z
dc.date.issued2025-06-11
dc.date.submitted2025-06-11
dc.description.abstractIntrodução: A estenose valvar pulmonar (EPV) é uma cardiopatia congênita caracterizada pela obstrução do fluxo sanguíneo na via de saída do ventrículo direito, representando 8-10% das malformações cardíacas congênitas. A valvoplastia pulmonar por balão (VPB) é consagrada como terapia de primeira linha para esta condição, porém seus efeitos sobre a função ventricular direita não são completamente elucidados. Objetivo: Descrever o comportamento da função ventricular direita e variáveis valvares após valvoplastia pulmonar percutânea por balão em pacientes pediátricos portadores de estenose valvar pulmonar em um serviço de referência no nordeste brasileiro. Métodos: Estudo longitudinal observacional retrospectivo do tipo antes e depois incluindo 39 pacientes submetidos à VPB entre 2013 e 2023. Foram avaliadas variáveis ecocardiográficas da função ventricular direita (área fracional, onda S' do anel tricúspide, TAPSE), gradientes transvalvares pulmonares (médio, máximo e pico a pico) e repercussões sobre as valvas pulmonares e tricúspide nos períodos pré e pós-procedimento. Resultados: Observou-se predomínio do sexo feminino (56,4%), com mediana de idade de 1 ano. A função ventricular direita manteve-se preservada após o procedimento, sem alterações estatisticamente significativas nos parâmetros convencionais (p=1,00), embora tenha sido observada tendência de redução na avaliação longitudinal (r=-0,3). Os gradientes transvalvares tiveram redução significativa (gradiente pico a pico: -46,05 mmHg; p<0,0001; ²=0,8024). Houve aumento significativo na prevalência de insuficiência pulmonar pós-procedimento (p<0,0001), porém sem associação com a magnitude da queda do gradiente. Não foram observadas alterações significativas na função tricúspide ou na hipertrofia ventricular direita no período valiado. Conclusão: A valvoplastia pulmonar por balão esteve associada a redução dos gradientes transvalvares,, sem alteração da função ventricular direita no período imediato. O desenvolvimento de insuficiência pulmonar representou consequência frequente, porém independente da magnitude do efeito hemodinâmico. O remodelamento ventricular completo possivelmente requer período mais prolongado, justificando a ausência de alterações significativas na hipertrofia ventricular direita e na função tricúspide no seguimento inicial.
dc.description.abstractotherlanguage"Introduction: Pulmonary valve stenosis (PVS) is a congenital heart defect characterized by obstruction of blood flow in the right ventricular outflow tract, accounting for 8–10% of congenital cardiac malformations. Balloon pulmonary valvuloplasty (BPV) is established as the first-line therapy for this condition; however, its effects on right ventricular (RV) function remain incompletely elucidated. Objective:To describe the behavior of right ventricular function and valvular parameters following percutaneous BPV in pediatric patients with PVS treated at a reference center in northeastern Brazil. Methods: This retrospective longitudinal observational study with a before-and-after design included 39 patients who underwent BPV between 2013 and 2023. Echocardiographic variables assessed before and after the procedure included RV function parameters (fractional area change, tricuspid annular S’ wave, and TAPSE), pulmonary transvalvular gradients (mean, peak, and peak-to-peak), and impacts on the pulmonary and tricuspid valves. Results: There was a predominance of female patients (56.4%), with a median age of 1 year. RV systolic function remained preserved post-procedure, with no statistically significant changes in conventional parameters (p=1.00), although a trend toward reduction was noted in the longitudinal analysis (r=–0.3). Transvalvular gradients showed a significant reduction (peak-topeak gradient: –46.05 mmHg; p<0.0001; R²=0.8024). A significant increase in the prevalence of post-procedural pulmonary regurgitation was observed (p<0.0001), with no association to the magnitude of gradient reduction. No significant changes were found in tricuspid function or RV hypertrophy during the evaluation period. Conclusion: Balloon pulmonary valvuloplasty was associated with a reduction in transvalvular gradients, with no deterioration of RV systolic function in the immediate post-procedural period. Pulmonary regurgitation was a frequent consequence, though independent of the degree of hemodynamic relief. Complete ventricular remodeling likely requires a longer follow-up period, which may explain the absence of significant changes in RV hypertrophy and tricuspid function at early reassessment."
dc.identifier.NameoftheGraduateProgramMedicina e Saúde Humana
dc.identifier.Nameoftheareaof​​concentrationClínica Médica
dc.identifier.ResearchlinenameMétodos diagnósticos e terapêuticos em Doenças cardiovasculares
dc.identifier.developmentagencyCAPES
dc.identifier.numberofpages75
dc.identifier.urihttps://repositorio.bahiana.edu.br/handle/123456789/9828
dc.language.isopt
dc.subjectEstenose pulmonar valvar
dc.subjectValvoplastia pulmonar por balão
dc.subject.keywordotherlanguagePulmonary valve stenosis
dc.subject.keywordotherlanguageBalloon pulmonary valvuloplasty
dc.titleImpacto da valvoplastia pulmonar por balão em pacientes portadores de estenose pulmonar valvar em hospital terciário de Salvador – Bahia
dc.typeDissertação

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Aline do Aido Varanda Arouca - Impacto da valvoplastia pulmonar por balão em pacientes portadores de estenose pulmonar valvar em hospital terciário de Salvador – Bahia - 2025.pdf
Tamanho:
2.57 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.64 KB
Formato:
Item-specific license agreed upon to submission
Descrição: