Please use this identifier to cite or link to this item:
https://repositorio.bahiana.edu.br:8443/jspui/handle/bahiana/2958
Title: | Accuracy of Myocardial Biomarkers in the Diagnosis of Myocardial Infarction After Revascularization as Assessed by Cardiac Resonance: The Medicine, Angioplasty, Surgery Study V (MASS-V) Trial |
Other Titles: | The Annals of Thoracic Surgery |
Authors: | Melo, Rodrigo Morel Vieira de Hueb, Whady Gersh, Bernard J. Costa, Leandro Menezes Alves da Oikawa, Fernando Teiichi Costa Rezende, Paulo Cury Garzillo, Cibele Larrosa Lima, Eduardo Gomes Nomura, Cesar Higa Villa, Alexandre Volney Hueb, Alexandre Ciappina Strunz, Celia Maria Cassaro Favarato, Desiderio Takiuti, Myrthes Emy Albuquerque, Cicero Piva de Silva, Expedito Eustáquio Ribeiro da Ramires, Jose Antonio Franchini Kalil Filho, Roberto |
Issue Date: | Jun-2016 |
Abstract: | dial necrosis biomarkers and electrocardiographic abnormalities after revascularization procedures has resulted in a change in the myocardial infarction (MI) definition. Methods. Patients with stable multivessel disease who underwent percutaneous or surgical revascularization were included. Electrocardiograms and concentrations of high-sensitive cardiac troponin I (cTnI) and creatine kinase (CK)-MB were assessed before and after procedures. Cardiac magnetic resonance and late gadolinium enhancement were performed before and after procedures. MI was defined as more than five times the 99th percentile upper reference limit for cTnI and 10 times for CK-MB in percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG), respectively, and new late gadolinium enhancement for cardiac magnetic resonance. Results. Of the 202 patients studied, 69 (34.1%) underwent on-pump CABG, 67 (33.2%) off-pump CABG, and 66 (32.7%) PCI. The receiver operating characteristic curve showed the accuracy of cTnI for on-pump CABG, off-pump CABG, and PCI patients was 21.7%, 28.3%, and 52.4% and for CK-MB was 72.5%, 81.2%, and 90.5%, respectively. The specificity of cTnI was 3.6%, 9.4%, and 42.1% and of CK-MB was 73.2%, 86.8%, and 96.4%, respectively. Sensitivity of cTnI was 100%, 100%, and 100% and of CK-MB was 69.2%, 64.3%, and 44.4%, respectively. The best cutoff of cTnI for on-pump CABG, off-pump CABG, and PCI was 6.5 ng/mL, 4.5 ng/mL, and 4.5 ng/mL (162.5, 112.5, and 112.5 times the 99th percentile upper reference limit) and of CK-MB was 37.5 ng/mL, 22.5 ng/mL, and 11.5 ng/mL (8.5, 5.1, and 2.6 times the 99th percentile upper reference limit), respectively. Conclusions. Compared with cardiac magnetic resonance, CK-MB was more accurate than cTnI for diagnosing MI. These data suggest a higher troponin cutoff for the diagnosis of procedure-related MI. |
URI: | http://www7.bahiana.edu.br//jspui/handle/bahiana/2958 |
Appears in Collections: | Artigos Completos Publicados em Periódicos |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ARTIGO - RODRIGO MELO - 2016.pdf | 498,31 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.